Summary
This video provides an overview of the Compact spray machine home screen, explaining the purpose of each icon and tab used for operation, cleaning, alarms, recipes, manual control, maintenance, and production monitoring.
Quick Guide
Interlock Status
Green icon: Machine is synchronized with upstream/downstream equipment.
Not green: Machine operates standalone.
Cleaning Modes
Hand icon: Moves reciprocator to center for manual gun cleaning.
Mop icon: Automatically sprays all guns programmed in the active recipe continuously until stopped.
Alarms
X icon: Clear alarms.
Triangle icon:
View active alarms
Access alarm history/records
Recipe Page
Displays:
Active recipe name and number
Guns enabled
Conveyor speed
Overspray values
Equipment Editor
Stores up to four setups:
Gun X/Y positioning
Gun angle
Compensation settings
Applies to Reciprocator A and B
System Settings (Swiss Army Knife)
Password protected
Includes:
Energy-saving mode
Time delays
VFD adjustments
Access limited to management/supervisors
Manual Operation Page
Adjust:
Intake air
Conveyors
Reciprocators
Guns
Photo bar
PLC inputs/outputs
Manual color change and fluid controls available here.
Production Data
Displays:
Power-on time
Working time
Sprayed square meters
Recovered square meters
Number of pieces produced
Reset by clearing data from this page.
Maintenance Records
Shows all scheduled maintenance items.
Clear each item after completing maintenance.
Operating Modes
Manual Mode: Start/stop and operate everything from the manual page.
Automatic Mode:
Press Start
Verify interlock status
Reciprocator status changes red → yellow → green
Key Notes
Always confirm correct mode before production.
Alarm and maintenance icons should never be ignored.
Home screen provides full operational status at a glance.