Summary

This video provides an overview of the Compact spray machine home screen, explaining the purpose of each icon and tab used for operation, cleaning, alarms, recipes, manual control, maintenance, and production monitoring.


Quick Guide

Interlock Status

  • Green icon: Machine is synchronized with upstream/downstream equipment.

  • Not green: Machine operates standalone.


Cleaning Modes

  • Hand icon: Moves reciprocator to center for manual gun cleaning.

  • Mop icon: Automatically sprays all guns programmed in the active recipe continuously until stopped.


Alarms

  • X icon: Clear alarms.

  • Triangle icon:

    • View active alarms

    • Access alarm history/records


Recipe Page

  • Displays:

    • Active recipe name and number

    • Guns enabled

    • Conveyor speed

    • Overspray values


Equipment Editor

  • Stores up to four setups:

    • Gun X/Y positioning

    • Gun angle

    • Compensation settings

  • Applies to Reciprocator A and B


System Settings (Swiss Army Knife)

  • Password protected

  • Includes:

    • Energy-saving mode

    • Time delays

    • VFD adjustments

  • Access limited to management/supervisors


Manual Operation Page

  • Adjust:

    • Intake air

    • Conveyors

    • Reciprocators

    • Guns

    • Photo bar

    • PLC inputs/outputs

  • Manual color change and fluid controls available here.


Production Data

Displays:

  • Power-on time

  • Working time

  • Sprayed square meters

  • Recovered square meters

  • Number of pieces produced

Reset by clearing data from this page.


Maintenance Records

  • Shows all scheduled maintenance items.

  • Clear each item after completing maintenance.


Operating Modes

  • Manual Mode: Start/stop and operate everything from the manual page.

  • Automatic Mode:

    1. Press Start

    2. Verify interlock status

    3. Reciprocator status changes red → yellow → green


Key Notes

  • Always confirm correct mode before production.

  • Alarm and maintenance icons should never be ignored.

  • Home screen provides full operational status at a glance.